Oxygen not included cool steam vent. Cool Steam Vent Oxygen Not Included A Screenshot o...

The range of medical oxygen cylinder sizes goes from M-2 to M-250 a

SPOM, OXYGEN: 3 KG/S. This SPOM is the so-called "Full Rodriguez". It generates 2.975 kg/second of oxygen. Note: use gold (or better) for things that can overheat. The upper section can be fully enclosed, as the hydrogen cools the top level. What material to build the liquid pipes out of depends on the temperature of your incoming water.the water thats coming out of that geyser is obviously hot. to get rid of that you can just pump the water inside of a cold biome, make sure that the water is spending enough time inside that cold biome to temp exchange. Then just dump it to your main water storage. be careful about using gold amalgam at the water pump that you will be ...This build heats the steam and feeds it to steam tur... You'll need plastic to build this. (I said "early game" in the video, it's not really, because plastic.) This build heats the steam and ...This means with one steam room above 125 °C, the steam from a Cool Steam Vent can be sucked up. It also means, it can take in steam that is much hotter. One port above 500 °C Steam (0.4 kg/s) from a Steam Vent on one side, and three ports above 135 °C Steam (1.2 kg/s) are effectively 1.6 kg/s of 226.25 °C Steam and produce 850 W.Cool steam vent + refinment - [Oxygen Not Included] - General Discussion - Klei Entertainment Forums. By FiannaTiger, May 9, 2019 in [Oxygen Not Included] - General Discussion. Could have a complete cycle of vent/dormant without over pressuring the room with the turbine running 100%. Drain the heat out of the petroleum …the water thats coming out of that geyser is obviously hot. to get rid of that you can just pump the water inside of a cold biome, make sure that the water is spending enough time inside that cold biome to temp exchange. Then just dump it to your main water storage. be careful about using gold amalgam at the water pump that you will be ...Right part is the cool steam vent. If you close it, you will see the temp rising above 100 degree, which lead the vent to expulse steam, and not water. Steam will condensate to water once you cooled below 99.4 degree. The right side tempshift are in igneous rock, to tank the heat generated.Learn how to tame different types of geysers, such as Hydrogen Vent, Metal Volcano, and Natural Gas Vent, and how to use them for resources and power generation. Find out the …️ ️ Hey You ️ ️00:00 Cool Steam Vent01:22 Partes del sistema04:00 Construccion31:41 Sistema de Liquido Fresco40:18 Sistema Final💥 Discord Oficial del Cana...Yes, you can use it for water. You'll likely have to cool the water down some, to not overheat your base, but it's perfectly usable water. #1. Xilo The Odd Nov 2, 2020 @ 8:57pm. yeah there are lots of uses for it, making water out of its steam is the primary go to way to go. later down the line i advise setting it up for steam power.I use CO2 in a radiant pipe in the cool steam vent's room to cool the steam. When the CO2 is hot, I give it to my slicksters or you can send it to the space. I store the gas in a tank under the vent as well I can loop the gas for free. I use automated valve with thermo sensor to extract the hot gas.Pump your condensed ~95 degrees hot geyser water into the 'optional water input' until the coolant is about 100 degrees, then use the sieve to remove all that heat and refill the polluted water coolant. Then back to using geyser water, etc. Just remember to update the valve value, otherwise you'll freeze the water in the pipes.Steam will rise/fill the room. The underside of the cool slush geyser will be made with metal tiles. The steam will touch these metal tiles and condense. Then the water will be pumped out. This makes the water in the bottom room about 95 degrees. It then gets converted into oxygen at 70 degrees. Deleting 25 degrees in the process.Cool steam geysers aren't terribly wild either. A low tech colony can simply watch the steam cool down and harness the hot water right away. The full heat output takes a considerable amount of time to become a real obstacle, enough time to build up higher tier solutions with it.Cooling down the steam vent's output is power-negative. Heating up the steam from a cool steam vent via an aquatuner cooling the turbine output water will break even and be power-neutral, unless you try to cool the water below about 70C. The output water is pretty much an ideal temperature for use in a SPOM to make oxygen.Whats the point of analyzing gysers and vents? Found a cool steam vent and chlorine vent and analyzed them. Nothing really happened other than a weird thingy my dupes placed on them. So whats the point in doing that? This thread is archived. New comments cannot be posted and votes cannot be cast. 5.Jan 20, 2022 · cswiger Jan 20, 2022 @ 11:09pm. Oxygen floats above steam and will block a Steam Turbine from running. CO2 will not block a Steam Turbine because it sinks below steam. So some designs don't care about some CO2 being around; others might lose resources because the vent/geyser over-pressurizes. Cool Steam Vent Oxygen Not Included A Screenshot of Oxygen Not Included By: Aleddra This is what i have. Refinery -> Atmos Suits -> Cool Steam Vent The heat is not a major factor in that location, for the vent anyway. But I don't know how to cool the steam water. I could use a screenshot or something. Thanks.I'm not sure about the chlorine/sand thing. One solution is to get salt and bleach stone from space; there may be other ways we haven't realized yet. Edit: The video actually mentions a way to produce a net gain of salt (and steam) using 4 geotuners on a salt water geyser and 5 on a chlorine vent.lso too many Infectious Polluted Oxygen vents in one place. I mean cool, plenty oxygen, but eventually I will have much more clay I know what to do with.When playing on arboria which doesn't get clay I was calculating this, and my infectious polluted o2 vent was producing an average of around 100g/s over its dormancy cycle.If the geyser has been analyzed, it should show how long it runs for, how frequently it vents gas, and how soon the next eruption is going to be. I'd recommend setting up a contained area, with a gas pump so that it can flow out, directly into gas tanks or a hydrogen generator. in fact i seal the area , after analyzing the meter says itself ...At the start you're fighting the temperature of the water in the steam room as well. Let it cool the area down and that should allow for steam to condense. I personally hate that design from FJ, it's over complex and low efficiency. "Heater" designs that raise the steam temperature to over 125 C are good.Of course it's not zero, but from a cold steam - or even a hot steam - vent, you're talking a few degrees over a thousand cycles. Oh no. The door and pipes are going to be the worst culprits. OTOH, insulated tiles aren't exactly cheap. Sure, there's plenty of rock to be had, but when you double wrap everything, it adds up quickly.HEHE. The Thermo Regulator is going to be fairly useless for cooling anything significantly. If you're in the early game, then you should be able to implement Wheezeworts in a locked Hydrogen chamber at least. From there, you can figure out a simple setup to cool the Steam Vent room; and then pump the water out.Setup. Make sure you have researched steam turbines, thermal regulators, and basic automation. Hydrogen will come from the vent at around 500°C (932°F), this is hot enough to break steel machines, so we will cool in 2 …Water from steam vents. Playing the spaced out DLC and my main base is running very low on water. I have 2 cool steam vents, the only problem is that the heat will kill my crops. I have 2 ideas on how to deal with it: 1. Using a hydrogen vent I can power some Thermo aquatuners to cool the water. 2.cswiger Aug 18, 2021 @ 9:11pm. Place metal tiles under the Desalinator and run your -10 C salt water in radiant pipes through them. Place some liquid on the floor-- 50 kg/tile or so-- to help move the heat from the Desalinator to the metal tile floor. Use a temp sensor to shut down the Desalinator before it overheats.Hydrogen vent taming. This design pumps out 130-140 degree hydrogen. Even if started in a vacuum, it won't overheat. Atmo Sensor (upper left): Above 4000g. Atmo Sensor (below gas pump): Above 1000g. Thermo Sensor: Below 135. Use steel for the Gas Pump. Note: Radiant liquid pipes help cool the steam turbine.What are Cool Steam vents best used for? They output way too cold of steam to actually allow Steam Turbines to take the steam in for power, and because they output steam, it may be a bit more finicky to try and get water out of it, so I was thinking what would these be best for?Pump your condensed ~95 degrees hot geyser water into the 'optional water input' until the coolant is about 100 degrees, then use the sieve to remove all that heat and refill the polluted water coolant. Then back to using geyser water, etc. Just remember to update the valve value, otherwise you'll freeze the water in the pipes.Whats the point of analyzing gysers and vents? Found a cool steam vent and chlorine vent and analyzed them. Nothing really happened other than a weird thingy my dupes placed on them. So whats the point in doing that? This thread is archived. New comments cannot be posted and votes cannot be cast. 5.Oxygen Not Included • Cool Steam Vent Setup Setup. Make sure you have researched steam turbines, thermal aquatuners, and basic automation. If you haven’t …The steam vent tamer. The build has steam vent as far right as it will go but you can move it one or two steps to the left as needed. Or you can flip it entirely. The power output of the build varies with the steam vent naturally but here I've just demonstrated the self-powered self-cooled version which only outputs 95C water.Introduction. Welcome to the mid-game guide for Oxygen Not Included. We’ll be picking up where we left off with the Oni Starter Guide on cycle 11 and we’ll be assuming all the steps taken and knowledge in the starter guide have been adopted. If you haven’t been through the starter guide or it has been a while, consider reading through it ...Automation extends your nat gas tremendously. yes I am, they only run ~60% of the time. I put the geyser stats through the geyser calculator and apparently it's a very good one. the main issue is that I don't get a lot of it's gas because the chamber it's in is at max pressure most of the time. #11.A molecule of oxygen contains two atoms. Oxygen never exists freely in nature but rather exists as a diatomic molecule, meaning two oxygen atoms bond together and share electrons. Other diatomic molecules include chlorine and hydrogen.Hello- I have this cool steam vent, which I have been setting up for water extraction, cooling of the water, etc. Then I realized that its water production is disappointingly low. It does not erupt very often, and its steam release is below average. I don't see anything "wrong" otherwise; the atmo pressure is pretty low, the temp is pretty …Oxygen Not Included • Cool Steam Vent Setup Taming a cool steam vent seems like a good idea at first, free water and power. However many players quickly learn that taming a cool steam vent is more difficult than it first appears. The steam is too cold to be used for a steam turbine, and heating up the steam is more trouble than it’s worth.For example a 5 kg steam tile has a heat capacity of 5 x 4.179 = ~21 (per degree), while a Gold Automation Bridge has a heat capacity of 5 x 0.129 / 5 = 0.129 (per degree), so even a simple fairly low pressure steam tile has much higher heat capacity than an automation bridge, and you'll get better performance out of a material with higher heat ...Your aquatuner should sit in the steam box below the turbine. You need a liquid that will tranfer its heat to the steam - run that liquid through the aquatuner. Also use a heat transfer tile or two to spread the heat from the aquatuner around the steam box. Most of your equipment will overheat at 75 or 125 degrees. You should probably check again the output of the cool steal vent ! You can usually get an average output of around 2kg/s of cold water out of it. The challenge is usually to have the steam vent not overpresurise (at 5kg/cell) You can do that with a thermal aquatuner cycling water in the chamber at a target temp of around 80°C They are not ...Salt Water Geyser is a renewable source of Salt Water which can be found in the Tide Pool Biome. One uncovered Salt Water Geyser is guaranteed to spawn in a Tide Pool Biome and more covered ones may be found in such a biome as well. Like all other Geysers, the Salt Water Geyser can overpressurize. It will emit until the pressure in the tile above its …Cool Steam Vent - Oxygen Not IncludedBug - The gas turns into a liquid teleport through the tiles to the top.Cách xử lý mạch hơi nước mát và nén nước tự động.Gaming. Browse all gaming. Oxygen Not Included HowTo - Make use of a cool steam vent In this video I am showing a setup to cool down the steam from a cold …HEHE. The Thermo Regulator is going to be fairly useless for cooling anything significantly. If you're in the early game, then you should be able to implement Wheezeworts in a locked Hydrogen chamber at least. From there, you can figure out a simple setup to cool the Steam Vent room; and then pump the water out.Sending in water above 70°C into the electrolyzer will destroy some heat yes, but if you are dumping ice into the cool steam vent chamber you don't have to care about what temperature the water is. It could be 50, 70 or 90. Does not matter. In any case the oxygen will be colder than if you sent in 95°C water from a steam turbine.Oxygen Not Included > General Discussions > Topic Details. Peacemaker Sep 28, 2018 @ 9:47am. Steam turbine on Steam vent. Hi guys. I cant make it work properly. Its not hot enough, or its underpressured. Once I reach the both goals, the temperature drops a lot (and air pressure too) and turbine shuts off in 5 seconds.Cool Steam Vent. A highly pressurized vent that periodically erupts with Steam. Max Pressure. 5 Kg. Avg. Emission Rate. 1 Kg/s - 2 Kg/s. Total Eruption Period. 60 s - 1140 s. % Active of Eruption Period.The presented method is a simple and low-cost design will enable you to tame a Hydrogen Vent using mid-game technology. While not a perfect design, this method will allow you to take advantage of Hydrogen power at an early stage of the game and enjoy trouble-free performance for hundreds of cycles. Written by afcq5. Oxygen Not Included.Directly right of the cool steam vent. Natural gas: 1. Find the iron volcano first. 2. Then, go slightly up and right. It's in the slime biome just to the right of the volcano. Steam: 1. Find the iron volcano first. 2. The steam vent is quite a ways almost directly up from there. You'll find one of the (rather tiny) cold biomes as a bonus!Apr 9, 2021 · To cool down water you can use aquatuners. This devide decrease incoming liquid temperature by 14C and equivalent of that heat removed is spread around the aquatuner. So it doesn't remove heat, it just moves it from liquid to enviroment surrounding. You need to figure out a way to keep aquatuner from overheating. Apr 3, 2021 · Hello everyone! Today, we're hooking up our first Steam Vent in the base to resupply our water. Hope you enjoy!:)Oxygen Not Included is a space colony simula... 2. catwhowalksbyhimself • 6 mo. ago. You only need 1 geotuner to get cool steam vents to turbine temps. Turn a slight power use to condense the steam into a self-powering tamer. Haven't actually tried it yet, but it is planned. 2. Oh_IHateIt • 6 mo. ago. My first thought as well. But it sadly doesnt work.A Screenshot of Oxygen Not Included. By: cswiger. The AquaTuner is cooling a loop of Brine to 30C, controlled by the Pipe Thermo Sensor. This cools down the turbines. There's a pressure sensor set to 20kg, which opens the Liquid Vent and adds more water to the AquaTuner chamber as needed. This vent is active enough for it to be up around 190 C ...If both the Vent and pressure chamber are connected to a steam room, which in turn is cooled by a Steam Turbine, the Hydrogen's Temperature will easily drop down to 125°C. Even if the Hydrogen Vent yields ~700g/s while active, this is only (700x2.4x375) 630kDTU/s, and approximately a third to half of that averaged out over its active period.Step one is to vacuum the room so there will just be steam. You set loop pipe with the Aquatuner to cool around, especially around the Steam Generators. From that loop, you extract water when it gets too cold (to provide cold water elsewhere). With the water from the Steam Generators, you prioritize filling back that cold loop and you put the ... Feb 13, 2020 · lso too many Infectious Polluted Oxygen vents in one place. I mean cool, plenty oxygen, but eventually I will have much more clay I know what to do with.When playing on arboria which doesn't get clay I was calculating this, and my infectious polluted o2 vent was producing an average of around 100g/s over its dormancy cycle. The steam will rise up, hit the water and condense, dropping down, so make sure you got room below the steam vent to catch it. To cool the water on the airflow tiles, I'll use a temp sensor and loop it through an aquatuner when it starts getting warm. The aquatuner I have sitting in a steam turbine room to manage the heat.Oxygen Not Included > General Discussions > Topic Details. Bolero. Dec 22, 2020 @ 3:31am Steam turbine liquid vent Overpressure I had a Steam Turbine and Aquatuner setup. Aquatuner is working but the Steam Turbine wasn't. The water turned to steam already with no water left but the Steam Engine stopped working after with the …AT first, I just let it cool into water naturally, then pipe in the hot water directly into electrolyzers. It's much easier to cool the oxygen than the water. Later on I add a cooling loop to cool the oxygen, which also chills a cold box that I used to cool the steam into water. It's at this point that I box the steam vent in an insulate it. Sep 11, 2020 · This is a great guide for dealing with steam vents. YouTube™ Video: Cool Steam Vent Taming : Tutorial nuggets : Oxygen not included. Views: 444,116. How to extract water from a cool steam vent. It is easier to cool the water down than to heat it up for a steam turbine. #3. AlexMBrennan Sep 11, 2020 @ 3:07pm. The presented method is a simple and low-cost design will enable you to tame a Hydrogen Vent using mid-game technology. While not a perfect design, this method will allow you to take advantage of Hydrogen power at an early stage of the game and enjoy trouble-free performance for hundreds of cycles. Written by afcq5. Oxygen Not Included.Cool Steam Vent Tamer using your extra water from the bathrooms! Also kills the food poisoning germs in the process.Other Geyser Tamers Playlist! https://www... The Original SPOM (MK II) There are a few key moments in any Oxygen Not Included gamer's life. Moments that will forever change how you play the game. One such moment is likely to be when you build your first SPOM. A SPOM turns water into oxygen - and generates enough power in the process that it can power itself.5) Hydrogen vents produce just as much energy as a natural gas geyser. They don’t produce waste, which can either be a plus or a minus. They are harder to tame, but their extreme heat can be counteracted by spreading the heat into a steam chamber with tempshift plates and metal tiles. More power but more effort. a) If the pressure gets above 5kg/tile the vent overpressures and stops emitting. b) Using steam above 200°C for power production with a steam turbine, deletes heat without turning it into power (using all 5 inlets). Number a) is solved by using two steam turbines, which combined, can extract just as much steam as the vent emits (4kg/s).Your aquatuner should sit in the steam box below the turbine. You need a liquid that will tranfer its heat to the steam - run that liquid through the aquatuner. Also use a heat transfer tile or two to spread the heat from the aquatuner around the steam box. Most of your equipment will overheat at 75 or 125 degrees.Views: 70,594. This tutorial bite for Oxygen Not Included explains all types of geysers, vents and volcanoes as well as how to capture then effectively and use the outputs. Its nice rundown of all geyser types and in steam vents section has working loops for both steam vent typess. More details in Cooling bit video.ชื่อภาษาอังกฤษ: Cool Steam Vent “ปล่องไกเซอร์แรงดันสูงที่ปะทุเป็นระยะและพ่นไอน้ำออกมา ” ปล่องไอน้ำอุ่นเป็นไกเซอร์ที่ปะทุและพ่นไอน้ำออกมาในฤดู ...It's cycle 56, you don't have the tech or material to deal with a cool steam vent properly. Brick of the area with insulated tiles to keep it from cooking your base and come back to harness it in 100 or so cycles. Steam vent tamer tutorial Side note, the 5 batteries to one coal generator ratio is perfect, most players never learn that, nice ...According to the wiki, the average steam production of a cool steam vent is 1,5 kg/s. I spawned a bunch of vents and came out to this average for most of them as well, but this is including the dormant period.2. catwhowalksbyhimself • 6 mo. ago. You only need 1 geotuner to get cool steam vents to turbine temps. Turn a slight power use to condense the steam into a self-powering tamer. Haven't actually tried it yet, but it is planned. 2. Oh_IHateIt • 6 mo. ago. My first thought as well. But it sadly doesnt work.This build heats the steam and feeds it to steam tur... You'll need plastic to build this. (I said "early game" in the video, it's not really, because plastic.) This build heats the steam and ...Oxygen Not Included > General Discussions > Topic Details. Peacemaker Sep 28, 2018 @ 9:47am. Steam turbine on Steam vent. Hi guys. I cant make it work properly. Its not hot enough, or its underpressured. Once I reach the both goals, the temperature drops a lot (and air pressure too) and turbine shuts off in 5 seconds.First, make your pumps and anything else that will be in the heat out of Gold Amalgam. It's the only thing that currently can handle those temps. Second try to isolate your base from the hot water and steam with airlocks and insulated tiles. The main problem will be the water, which has to be cooled down if you wish to use it.Then put a few (two or more) (If memory serves, two is enough) steam turbines above it. Note: the steam turbines will need some form of cooling, as they will get hot quickly. The steam vent outputs +500C steam. The steam turbines will generate power (as long as the steam is above +125C) and +95C water.Dec 12, 2021 · The video you watched might have been a normal steam vent, which is hotter (500ºc). Cool steam vents produce steam at 110ºc, which is really close to its condensation point (99.4ºc), so it turns into water really fast. Just surround it with insulated tiles, so it doesn't heat the surrounding area, then the only problem you will have is to ... This means with one steam room above 125 °C, the steam from a Cool Steam Vent can be sucked up. It also means, it can take in steam that is much hotter. One port above 500 °C Steam (0.4 kg/s) from a Steam Vent on one side, and three ports above 135 °C Steam (1.2 kg/s) are effectively 1.6 kg/s of 226.25 °C Steam and produce 850 W.Considering the low output of Polluted Oxygen Vents and the low SHC of Oxygen, the power needed is minimal, even when using the less efficient Thermo-Regulators. This also means the counterflow heat exchanger doesn't need to be big. On the other hand, because Polluted Oxygen and Oxygen have the same weight, that heat exchanger MUST be vertical ...Whats the point of analyzing gysers and vents? Found a cool steam vent and chlorine vent and analyzed them. Nothing really happened other than a weird thingy my dupes placed on them. So whats the point in doing that? This thread is archived. New comments cannot be posted and votes cannot be cast. 5.Hydrogen vent taming. This design pumps out 130-140 degree hydrogen. Even if started in a vacuum, it won't overheat. Atmo Sensor (upper left): Above 4000g. Atmo Sensor (below gas pump): Above 1000g. Thermo Sensor: Below 135. Use steel for the Gas Pump. Note: Radiant liquid pipes help cool the steam turbine.SPOM, OXYGEN: 3 KG/S. This SPOM is the so-called "Full Rodriguez". It generates 2.975 kg/second of oxygen. Note: use gold (or better) for things that can overheat. The upper section can be fully enclosed, as the hydrogen cools the top level. What material to build the liquid pipes out of depends on the temperature of your incoming water.Oxygen Not Included > General Discussions > Topic Details. Bolero. Dec 22, 2020 @ 3:31am Steam turbine liquid vent Overpressure I had a Steam Turbine and Aquatuner setup. Aquatuner is working but the Steam Turbine wasn't. The water turned to steam already with no water left but the Steam Engine stopped working after with the …a) If the pressure gets above 5kg/tile the vent overpressures and stops emitting. b) Using steam above 200°C for power production with a steam turbine, deletes heat without turning it into power (using all 5 inlets). Number a) is solved by using two steam turbines, which combined, can extract just as much steam as the vent emits (4kg/s).Hello everyone!Today, we're installing the contraption that is gonna be responsible for our water production in the future. Combining 2 slush geysers with a ...Using a thermo regulator with in a room filled with hydrogen + radiant pipes will do the trick for cooling the steam enough to condense, then you can pump the water elsewhere to use. As far as researching exosuits or wait till it’s dormant. Sowelu • 4 yr. ago.Best way I have found so far for this is to abuse how the water works by slightly overfilling a water layer with about 100-200g and have that top layer be cooled by something like a pipe with cold gass or cold water pipe. It will transfer that straight down like this: Oxygen Not Included. A Screenshot of Oxygen Not Included. Say we start with 95C water condensed from a cool steam vent. Use a gold aquatuner to dump heat into it up to 170C. That's 313 kJ of cooling potential (per kg of water electrolyzed). The output oxygen will need to be cooled and for the sake of simplicity let's not bother separating out the hydrogen.Cooling down the steam vent's output is power-negative. Heating up the steam from a cool steam vent via an aquatuner cooling the turbine output water will break even and be power-neutral, unless you try to cool the water below about 70C. The output water is pretty much an ideal temperature for use in a SPOM to make oxygen.Pump your condensed ~95 degrees hot geyser water into the 'optional water input' until the coolant is about 100 degrees, then use the sieve to remove all that heat and refill the polluted water coolant. Then back to using geyser water, etc. Just remember to update the valve value, otherwise you'll freeze the water in the pipes.ชื่อภาษาอังกฤษ: Cool Steam Vent “ปล่องไกเซอร์แรงดันสูงที่ปะทุเป็นระยะและพ่นไอน้ำออกมา ” ปล่องไอน้ำอุ่นเป็นไกเซอร์ที่ปะทุและพ่นไอน้ำออกมาในฤดู .... Aug 7, 2018 · Heat capacity of steam/water is 4.179According to the wiki, the average steam production of a coo It depends on how a player progresses. If you are using water for lice loaf, got your electrolyzers set up early, etc.... you could easily be out of water. Especially if you didn't find it for the first 100-150 cycles. tip: save electricity and water, turn the lice into picked meals.Considering the low output of Polluted Oxygen Vents and the low SHC of Oxygen, the power needed is minimal, even when using the less efficient Thermo-Regulators. This also means the counterflow heat exchanger doesn't need to be big. On the other hand, because Polluted Oxygen and Oxygen have the same weight, that heat exchanger MUST be vertical ... Cool steam vents do not start out hot enoug For the rest, one set-up is to have a large tank below which you cool sort-of "best-effort" with whatever the direct cooling for the vent has left, and then a 2nd Steam Turbine/Aquatuner that you use for target cooling to exactly the desired target temperature. This is a self-powered late-game cool steam ve...

Continue Reading